zigbee-bridge reads one TOML file, /etc/zigbee-bridge/config.toml unless --config FILE names another. Only the coordinator’s port is required:

[serial]
port = "/dev/serial/by-id/usb-Nabu_Casa_SkyConnect_v1.0_..."

Everything else has a default. Unknown keys and wrong types are errors, so a typo stops the bridge at startup with the file, line and key, instead of being silently ignored. The configuration reference lists every key; it is generated from the code, so it is always current.

A JSON Schema generated from the same code lets an editor with TOML schema support (Taplo, or VS Code’s Even Better TOML) complete and check the file. Point it at the schema with a first line of:

#:schema https://pulzar-net.github.io/zigbee-bridge/config.schema.json
Table What it sets
[serial] the coordinator’s port: a serial device or tcp://host:port, baud rate, flow control, and (since 0.2.0) the coordinator family: auto, ezsp, znp or deconz
[mqtt] broker host and port, user name, a password file, client id, base topic, keep-alive, whether device state is retained
[homeassistant] discovery on or off, the discovery prefix, Home Assistant’s status topic
[network] channel and transmit power of a new network, and whether a different network on the coordinator may be replaced
[join] whether only devices with an install code may join, and whether pre-Zigbee 3.0 devices may stay
[data] the data directory
[ota] where device firmware images are kept (since 0.2.0)

config.example.toml in the repository sets every key to its default, with comments. CI checks that it parses.

# zigbee-bridge configuration. Only [serial] is required.
[serial]
# A serial device, or tcp://host:port for a network coordinator or the
# simulator (zigbee-ncp-sim).
port = "/dev/ttyUSB0"
baud = 115200
# none, hardware (RTS/CTS) or software
flow_control = "none"
# auto (probe the port), ezsp (Silicon Labs EmberZNet), znp (TI Z-Stack) or
# deconz (ConBee, RaspBee)
adapter = "auto"
[mqtt]
host = "localhost"
port = 1883
# username = "zigbee"
# password_file = "/etc/zigbee-bridge/mqtt-password"
client_id = "zigbee-bridge"
base_topic = "zigbee"
retain_state = true
[homeassistant]
enabled = true
discovery_prefix = "homeassistant"
status_topic = "homeassistant/status"
[network]
# Used once, when the bridge creates data/network.json with random PAN ids
# and network key. To supply your own keys, write that file before the
# first start.
channel = 15
# tx_power = 8
# Leave a different network found on the coordinator and form ours.
# Off by default: an unknown network is never wiped silently.
replace_other = false
[join]
install_code_only = false
# Accept devices older than Zigbee 3.0, which never get a unique link key.
allow_legacy = true
[data]
dir = "/var/lib/zigbee-bridge"
[ota]
# A directory of device firmware images (OTA files); <data.dir>/ota when
# unset. An image goes to a device only after an ota_update request for it.
# dir = "/var/lib/zigbee-bridge/ota"

Use the stable path under /dev/serial/by-id/ for a USB coordinator: it names the device, while /dev/ttyUSB0 and /dev/ttyACM0 can swap when another USB serial device is plugged in. For a coordinator on the network (such as an SMLIGHT SLZB-06M in coordinator mode), use tcp://address:6638 with the port its web interface shows.

baud must match the firmware. Most EmberZNet and Z-Stack coordinator firmware runs at 115200, the default. flow_control must also match: Silicon Labs firmware builds named ncp-uart-hw use RTS/CTS (hardware), builds named ncp-uart-sw use XON/XOFF (software). Run zigbee-bridge probe PORT --baud N to check a setting before using it.

The MQTT password is never in the configuration file: mqtt.password_file names a file that holds it. Keep that file readable by the bridge’s user only.

The network key is not in the configuration either. On first start the bridge generates a random one and writes it, with the PAN ids and channel, to network.json in the data directory (mode 0600):

{
"channel": 15,
"pan_id": "0x1a62",
"extended_pan_id": "dd7c5e3a9b1f4e02",
"network_key": "0123456789abcdef0123456789abcdef"
}

To run a network with keys you manage yourself, write this file before the first start. After the first start, network.json is the source of truth: changing network.channel in the configuration does not move an existing network.

File What it holds Written
network.json network key, PAN ids, channel once, on first start
devices.json every device: addresses, names, interview, endpoints when a device record changes, batched
backup.json the latest network backup, in the open coordinator backup format hourly and after every join or leave
restore-pending.json a backup staged by zigbee-bridge restore until the next start restores it
ota/ device firmware images for ota_update, unless ota.dir is set by you

All of them are written atomically (a temporary file, then a rename) and are readable by their owner only, because they hold the network key. Back up the whole directory. Backup and restore explains moving a network to a new coordinator.

The bridge logs to standard error. Set the level with RUST_LOG:

RUST_LOG What you see
unset or info startup, joins, interviews, errors
debug every request and report
info,zigbee_ezsp=trace every EZSP command and callback
info,zigbee_ash=trace every serial frame