zigbee-bridge reads one TOML file, /etc/zigbee-bridge/config.toml unless
--config FILE names another. Only the coordinator’s port is required:
[serial]port = "/dev/serial/by-id/usb-Nabu_Casa_SkyConnect_v1.0_..."Everything else has a default. Unknown keys and wrong types are errors, so a typo stops the bridge at startup with the file, line and key, instead of being silently ignored. The configuration reference lists every key; it is generated from the code, so it is always current.
A JSON Schema generated from the same code lets an editor with TOML schema support (Taplo, or VS Code’s Even Better TOML) complete and check the file. Point it at the schema with a first line of:
#:schema https://pulzar-net.github.io/zigbee-bridge/config.schema.jsonThe tables
Section titled “The tables”| Table | What it sets |
|---|---|
[serial] |
the coordinator’s port: a serial device or tcp://host:port, baud rate, flow control, and (since 0.2.0) the coordinator family: auto, ezsp, znp or deconz |
[mqtt] |
broker host and port, user name, a password file, client id, base topic, keep-alive, whether device state is retained |
[homeassistant] |
discovery on or off, the discovery prefix, Home Assistant’s status topic |
[network] |
channel and transmit power of a new network, and whether a different network on the coordinator may be replaced |
[join] |
whether only devices with an install code may join, and whether pre-Zigbee 3.0 devices may stay |
[data] |
the data directory |
[ota] |
where device firmware images are kept (since 0.2.0) |
A complete example
Section titled “A complete example”config.example.toml
in the repository sets every key to its default, with comments. CI checks
that it parses.
# zigbee-bridge configuration. Only [serial] is required.
[serial]# A serial device, or tcp://host:port for a network coordinator or the# simulator (zigbee-ncp-sim).port = "/dev/ttyUSB0"baud = 115200# none, hardware (RTS/CTS) or softwareflow_control = "none"# auto (probe the port), ezsp (Silicon Labs EmberZNet), znp (TI Z-Stack) or# deconz (ConBee, RaspBee)adapter = "auto"
[mqtt]host = "localhost"port = 1883# username = "zigbee"# password_file = "/etc/zigbee-bridge/mqtt-password"client_id = "zigbee-bridge"base_topic = "zigbee"retain_state = true
[homeassistant]enabled = truediscovery_prefix = "homeassistant"status_topic = "homeassistant/status"
[network]# Used once, when the bridge creates data/network.json with random PAN ids# and network key. To supply your own keys, write that file before the# first start.channel = 15# tx_power = 8# Leave a different network found on the coordinator and form ours.# Off by default: an unknown network is never wiped silently.replace_other = false
[join]install_code_only = false# Accept devices older than Zigbee 3.0, which never get a unique link key.allow_legacy = true
[data]dir = "/var/lib/zigbee-bridge"
[ota]# A directory of device firmware images (OTA files); <data.dir>/ota when# unset. An image goes to a device only after an ota_update request for it.# dir = "/var/lib/zigbee-bridge/ota"Choosing the port
Section titled “Choosing the port”Use the stable path under /dev/serial/by-id/ for a USB coordinator: it
names the device, while /dev/ttyUSB0 and /dev/ttyACM0 can swap when
another USB serial device is plugged in. For a coordinator on the network
(such as an SMLIGHT SLZB-06M in coordinator mode), use tcp://address:6638
with the port its web interface shows.
baud must match the firmware. Most EmberZNet and Z-Stack coordinator
firmware runs at 115200, the default. flow_control must also match:
Silicon Labs firmware builds named ncp-uart-hw use RTS/CTS (hardware),
builds named ncp-uart-sw use XON/XOFF (software). Run
zigbee-bridge probe PORT --baud N to check a setting before using it.
Secrets
Section titled “Secrets”The MQTT password is never in the configuration file: mqtt.password_file
names a file that holds it. Keep that file readable by the bridge’s user
only.
The network key is not in the configuration either. On first start the
bridge generates a random one and writes it, with the PAN ids and channel,
to network.json in the data directory (mode 0600):
{ "channel": 15, "pan_id": "0x1a62", "extended_pan_id": "dd7c5e3a9b1f4e02", "network_key": "0123456789abcdef0123456789abcdef"}To run a network with keys you manage yourself, write this file before the
first start. After the first start, network.json is the source of truth:
changing network.channel in the configuration does not move an existing
network.
The data directory
Section titled “The data directory”| File | What it holds | Written |
|---|---|---|
network.json |
network key, PAN ids, channel | once, on first start |
devices.json |
every device: addresses, names, interview, endpoints | when a device record changes, batched |
backup.json |
the latest network backup, in the open coordinator backup format | hourly and after every join or leave |
restore-pending.json |
a backup staged by zigbee-bridge restore |
until the next start restores it |
ota/ |
device firmware images for ota_update, unless ota.dir is set |
by you |
All of them are written atomically (a temporary file, then a rename) and are readable by their owner only, because they hold the network key. Back up the whole directory. Backup and restore explains moving a network to a new coordinator.
Logging
Section titled “Logging”The bridge logs to standard error. Set the level with RUST_LOG:
RUST_LOG |
What you see |
|---|---|
unset or info |
startup, joins, interviews, errors |
debug |
every request and report |
info,zigbee_ezsp=trace |
every EZSP command and callback |
info,zigbee_ash=trace |
every serial frame |
Keys are never logged at any level.